sd_bus_set_server(3) — Linux manual page

NAME | SYNOPSIS | DESCRIPTION | RETURN VALUE | NOTES | HISTORY | SEE ALSO | NOTES | COLOPHON

SD_BUS_SET_SERVER(3)        sd_bus_set_server       SD_BUS_SET_SERVER(3)

NAME         top

       sd_bus_set_server, sd_bus_is_server, sd_bus_get_bus_id,
       sd_bus_set_bus_client, sd_bus_is_bus_client, sd_bus_set_monitor,
       sd_bus_is_monitor - Configure connection mode for a bus object

SYNOPSIS         top

       #include <systemd/sd-bus.h>

       int sd_bus_set_server(sd_bus *bus, int b, sd_id128_t id);

       int sd_bus_is_server(sd_bus *bus);

       int sd_bus_get_bus_id(sd_bus *bus, sd_id128_t *id);

       int sd_bus_set_bus_client(sd_bus *bus, int b);

       int sd_bus_is_bus_client(sd_bus *bus);

       int sd_bus_set_monitor(sd_bus *bus, int b);

       int sd_bus_is_monitor(sd_bus *bus);

DESCRIPTION         top

       sd_bus_set_server() configures the bus object as a server for
       direct D-Bus connections.  b enables/disables the server mode. If
       zero, the server mode is disabled. Otherwise, the server mode is
       enabled. Configuring a bus object as a server is required to
       allow establishing direct connections between two peers without
       going via the D-Bus daemon.  id must contain a 128-bit integer id
       for the server. If clients add a guid field to their D-Bus
       address string, the server id must match this guid or the D-Bus
       authentication handshake will fail. If no specific id is defined
       for the server, sd_id128_randomize(3) can be used to generate a
       random id instead.

       sd_bus_is_server() returns whether the server mode is enabled for
       the given bus object.

       sd_bus_get_bus_id() stores the D-Bus server id configured using
       sd_bus_set_server() (for server bus objects) or received during
       D-Bus authentication (for client bus objects) in id.

       sd_bus_set_bus_client() configures the bus object as a D-Bus
       daemon client.  b enables/disables the client mode. If zero, the
       client mode is disabled and the bus object should connect
       directly to a D-Bus server. Otherwise, the client mode is enabled
       and the bus object should connect to a D-Bus daemon. When
       connecting to an existing bus using any of the functions in the
       sd_bus_open(3) family of functions or any of the functions in the
       sd_bus_default(3) family of functions, the bus object is
       automatically configured as a bus client. However, when
       connecting to a D-Bus daemon by calling sd_bus_set_address(3)
       followed by sd_bus_start(3), the bus object should be manually
       configured as a bus client using sd_bus_set_bus_client(). By
       default, a bus object is not configured as a D-Bus daemon client.

       sd_bus_is_bus_client() returns whether the client mode is
       enabled/disabled for the given bus object.

       sd_bus_set_monitor() configures the bus object as a D-Bus monitor
       object.  b enables/disables the monitor mode. If zero, the
       monitor mode is disabled. If non-zero, the monitor mode is
       enabled. When the monitor mode is enabled, no messages may be
       sent via the bus object and it may not expose any objects on the
       bus. To start monitoring messages, call the
       org.freedesktop.DBus.Monitoring.BecomeMonitor method of the D-Bus
       daemon and pass a list of matches indicating which messages to
       intercept. See The D-Bus specification[1] for more information.

       sd_bus_is_monitor() returns whether the monitor mode is
       enabled/disabled for the given bus object.

RETURN VALUE         top

       On success, sd_bus_set_server(), sd_bus_get_bus_id(),
       sd_bus_set_bus_client() and sd_bus_set_monitor() return a
       non-negative integer. On failure, they return a negative
       errno-style error code.

       sd_bus_is_server(), sd_bus_is_bus_client() and
       sd_bus_is_monitor() return a positive integer when the server or
       client mode is enabled, respectively. Otherwise, they return
       zero.

   Errors
       Returned errors may indicate the following problems:

       -ECHILD
           The bus connection has been created in a different process,
           library or module instance.

           Added in version 246.

       -EPERM
           The bus connection has already been started.

           Added in version 246.

       -ENOPKG
           The bus cannot be resolved.

           Added in version 246.

       -EINVAL
           A required parameter was NULL or b was zero and id did not
           equal SD_ID128_NULL.

           Added in version 246.

       -ENOTCONN
           The bus is not connected.

           Added in version 246.

NOTES         top

       Functions described here are available as a shared library, which
       can be compiled against and linked to with the
       libsystemd pkg-config(1) file.

       The code described here uses getenv(3), which is declared to be
       not multi-thread-safe. This means that the code calling the
       functions described here must not call setenv(3) from a parallel
       thread. It is recommended to only do calls to setenv() from an
       early phase of the program when no other threads have been
       started.

HISTORY         top

       sd_bus_set_server(), sd_bus_is_server(), sd_bus_get_bus_id(),
       sd_bus_set_bus_client(), sd_bus_is_bus_client(),
       sd_bus_set_monitor(), and sd_bus_is_monitor() were added in
       version 246.

SEE ALSO         top

       systemd(1), sd-bus(3)

NOTES         top

        1. The D-Bus specification
           https://dbus.freedesktop.org/doc/dbus-specification.html#bus-messages-become-monitor

COLOPHON         top

       This page is part of the systemd (systemd system and service
       manager) project.  Information about the project can be found at
       ⟨http://www.freedesktop.org/wiki/Software/systemd⟩.  If you have
       a bug report for this manual page, see
       ⟨http://www.freedesktop.org/wiki/Software/systemd/#bugreports⟩.
       This page was obtained from the project's upstream Git repository
       ⟨https://github.com/systemd/systemd.git⟩ on 2024-06-14.  (At that
       time, the date of the most recent commit that was found in the
       repository was 2024-06-13.)  If you discover any rendering
       problems in this HTML version of the page, or you believe there
       is a better or more up-to-date source for the page, or you have
       corrections or improvements to the information in this COLOPHON
       (which is not part of the original manual page), send a mail to
       man-pages@man7.org

systemd 257~devel                                   SD_BUS_SET_SERVER(3)

Pages that refer to this page: sd-bus(3)sd_bus_add_match(3)systemd.directives(7)systemd.index(7)